Maxtor D540X-4K Computer Drive User Manual


 
ATA Bus Interface and ATA Commands
Maxtor D540X-4K 20.4/40.0/60.0/80.0 GB AT 6-7
Table 6-2 shows the supported subcommands of SET FEATURES organized by
feature name. The ID Word column shows if the current default setting can be
80 Major version number 003Eh
81 Minor version number 0015h
82 Command set supported 346Bh
83 Command set supported 5B01h
84 Command set/feature supported extension 4003h
85 Command set/feature enabled 3468h
86 Command set/feature enabled 1A01h
87 Command set/feature default 4003h
88 Ultra DMA mode 003Fh
89 Time required for security erase unit completion Variable
90 Time required for Enhanced security erase
completion
0000h
91 Current advanced power management value 0000h
92 Master Password Revision Code FFFEh
93 Hardware reset result Variable
94 acoustic management value 8080h
95-99 Reserved Reserved
100-103 Maximum user LBA address for 48-bit Address
feature set
777Fh,
0260h,
0000h,
0000h
104-126 Reserved Reserved
127 Removable Media Status Notification feature set
support
0000h
128 Security status 0001h
129-159 Vendor specific Reserved
160 CFA power mode 1 0000h
161-175 Reserved for assignment by the CompactFlash
Association
Reserved
176-254 Reserved Reserved
255 15-8
7-0
Integrity word checksum
Integrity word signature
Variable
41A5h