32
DESIGN SPECIFICATIONS
OPERATIONAL
Light Source: Visible Laser Diode 650 nm ± 10 nm
Laser Power: Less than 1 mW (peak)
Depth of Scan Field:
0 mm – 203 mm (0” – 8”) for 0.330 mm (13 mil) bar code at
default setting
Scan Speed: 72 scan lines per second
Scan Pattern: Single scan line
Minimum Bar Width: 0.127 mm (5.0 mil)
InfraRed Activation:
Long Range: 0 mm – 279 mm ± 51 mm (0” – 11” ± 2”)
Short Range: 0 mm – 102 mm ± 25 mm (0” – 4” ± 1”)
Decode Capability:
Autodiscriminates all standard bar codes for others call a
Metrologic service representative
System Interfaces:
RS232, PC Keyboard Wedge, Stand-Alone Keyboard,
OCIA, IBM 468X/469X, Light Pen Emulation, Laser
Emulation, RS232 with DSR
Print Contrast: 35% minimum reflectance difference
Number Characters
Read:
Up to 80 data characters
(Maximum number will vary based on symbology & density)
Roll, Pitch, Yaw: 42°, 68°, 52°
Beeper Operation: 7 tones or no beep
Indicators (LED)
Default Settings:
Green = laser on, ready to scan; Red = good read;
Yellow (MS9540 Only) = CodeGate button is inactive (on).
CodeGate button is active (off)
MECHANICAL
Length: 198 mm (7.8”)
Width: Handle - 45 mm (1.8”), Head - 78 mm (3.1”)
Depth: 40 mm (1.6”)
Weight: 149 g (5.25 oz)
ELECTRICAL
Input Voltage: 5VDC ± 0.25V
Power: Operating = 0.825 W, Standby = 0.600 W
Current:
Operating = 165 mA @ 5VDC, Standby
= 120 mA @ 5VDC
DC Transformers: Class 2; 5.2V @ 650 mA
Laser Class: CDRH: Class II; EN60825-1:1994/A11:1996 Class 1
EMC: FCC Class B
ENVIRONMENTAL
Temperature:
Operating = 0°C to 40° (32° to 104°F)
Storage = -40°C to 60°C (-40°F to 140°F)
Humidity: 5% to 95% relative humidity, non-condensing
Light Levels: Up to 4842 Lux (450 footcandles)
Shock: Designed to withstand 1.5 m (5’) drops
Contaminants: Sealed to resist airborne particulate contaminants
Ventilation: None required