Metrologic Instruments MS9500 Scanner User Manual


 
40
SCANNER AND CABLE TERMINATIONS (CONTINUED)
Cable Connector Configurations (Host End)
“Standard” PowerLink cable
9-pin D-type female connector to the PC
Pin Function
1 Shield Ground
2 RS-232 Transmit Output
3 RS-232 Receive Input
4 DTR Input/Light Pen Source
5 Power/Signal Ground
6
Light Pen Data
(DSR Out for -14 interfaces)
7 CTS Input
8 RTS Output
9+5VDC
Stand Alone Keyboard Power Link Cable
Pin Function
1 PC Data
2NC
3 Power Ground
4 +5VDC PC Power to KB
5 PC Clock
6NC
9-Pin D-Type Connector
95
61
4
2
1
3
65
6-Pin Male Mini-DIN Connector