Milan Technology MIL-SME801GLX Switch User Manual


 
98
5-4-2-2. Advanced Setting
MAC Address Entry Age-out Time:
Enter the number of seconds that an
inactive MAC address remains in the switch's address table. The valid range
is 300 to 765 seconds. Default is 300 seconds.
Max bridge transmit delay bound control:
Limits the packets queuing time
in the switch. If enabled, the packets that exceed the time limit in the queue
will be dropped. This valid values are 1sec, 2 sec, 4 sec and off. Default is 1
second.
Enable Low Queue Delay Bound:
Limits the low priority packets queuing
time in switch. If a low priority packet in the switch exceeds the Max Delay
Time, it will be sent. The valid range is 1 to 255 ms.
NOTE:
Make sure the “Max bridge transit delay bound control” is enabled
before enabling Delay Bound. The Enable Delay Bound only works under
“Max bridge transit delay bound control is enabled” situation.
Broadcast Storm Filter:
The threshold is the percentage of the port's total
bandwidth used by broadcast traffic. To configure broadcast storm control,
first enable it and then set the upper threshold for each individual port. When
broadcast traffic for a port rises above the threshold set, broadcast storm
control becomes active. The valid threshold values are 5%, 10%, 15%, 20%,
25% and OFF.