Lower DIP Switches:
SELECTION 1 2 3 4 5 6 7 8 DEFAULT
Flow Control
XON/XOFF ON OFF
RTS/CTS OFF ON
DTR OFF OFF DTR
Diagnostics
Normal Run Mode OFF Normal
Diagnostics Mode ON
Verifier
No Verifier
OFF No Verifier
Verifier Installed
ON
Supply Type/ Sensing
Die Cut or Edge Aperture (edge sensor) OFF OFF
Black Mark (center sensor) OFF ON Die Cut
Continuous (no sensor) ON OFF
Center Aperture (center sensor)
ON ON
Ribbon
Transfer OFF Transfer
Direct ON
Feed Mode
Continuous OFF Continuous
On-Demand ON