Moxa Technologies EDS-518A Series Switch User Manual


 
EDS-518A Series User’s Manual Featured Functions
3-15
V1, V2c Write/Read Community
Setting Description Factory Default
V1, V2c
Read/Write
Community
Uses a community string match with a
maximum of 30 characters for
authentication. The SNMP servers access
all objects with read/write permissions
using the community string private.
private
For SNMP V3, there are two levels of privileges for different accounts to access the EDS-518A.
Admin privilege allows access, and authorization to read and write the MIB file. User privilege
only allows reading the MIB file, but does not have authorization to write.
Admin Auth. Type (for SNMP V1, V2c, V3, and V3 only)
Setting Description Factory Default
No-Auth
Use admin. account to access objects.
No authentication
No
MD5-
Auth
Provide authentication based on the
HMAC-MD5 algorithms. 8-character
passwords are the minimum requirement
for authentication.
No
SHA-
Auth
Provide authentication based on the
HMAC-SHA algorithms. 8-character
passwords are the minimum requirement
for authentication.
No
Admin Data Encryption Key (for SNMP V1, V2c, V3, and V3 only)
Setting Description Factory Default
Enable
8-character data encryption key is the
minimum requirement for data encryption
(maximum of 30 characters)
No
Disable No data encryption No
User Auth. Type (for SNMP V1, V2c, V3 and V3 only)
Setting Description Factory Default
No-Auth
Use admin account or user account to
access objects. No authentication.
No
MD5-Auth
Provides authentication based on the
HMAC-MD5 algorithms. 8-character
passwords are the minimum requirement
for authentication.
No
SHA-Auth
Provides authentication based on the
HMAC-SHA algorithms. 8-character
passwords are the minimum requirement
for authentication.
No