MRV Communications, Inc. – Installation Manual
57
TS5000/4U1 (4E1 or 4T1)
Part Number
TS5000/4E1/V* or TS5000/4T1/V*
Model
TS5000/4E1 or TS5000/4T1
Standard P.N
TS5000/4E1/VS
Application /
Data Protocol
4E1: 4x2.048Mbps or 4T1: 4x1.55Mbps
G.703/G.704
Range
@ 3dB/km 6700 m
@ 5dB/km 5000 m
@ 10dB/km 3200 m
@ 17dB/km 2170 m
@ 30dB/km 1400 m
Minimum Range 400 m
Bit Error Rate Less than 1E-9 (unfaded)
Performance
MTBF 10 years
Light source 3 x Lasers
Wavelength 830-860 nm
Total Output power 85 mW
Transmitter
Beam divergence 2 mrad
Detector APD
Field of view 2 mrad
Receiver
Sensitivity -55 dBm
Type Electrical: E1: 75 Ohm or 120 Ohm, T1: 100 Ohm
Connectors Universal Connector
Cable STP or Coax
Interface
Cable Losses Supports Short and Long haul trunks
Power Supply
Factory set: 100-240 VAC @ 50/60 Hz or 35-60 VDC (V3 Version)
(30 W)
Operating Temp.
-30 °C to +50 °C
Storage Temp.
-50 °C to +70 °C
Humidity 95% non-condensing
Housing Weatherproof – IP 66
Environmental
Information
Eye safety Class 1M
Dimensions [mm] 790 X 390 X 556 (AD-5000: 250x353x432)
Unit 14 kg Weight
Accessories 21.5kg
Mechanical
Design
Modularity Modular Power supply
Indicators Airlink: Flag, Sync. E1 Ports: LED per port.
Receive Signal Strength (Digital Display),
Lasers status (3 LEDs)
Selectors
Termination, Electrical receive sensitivity, Line incoding, Local
Loopback, Remote Loopback, IP address setting
Dry Contact
6 Dry Contact outputs: 4 for interface ports
1 for air-link flag
1 for air-link sync
Diagnostics
Indicators
and
Selectors
Management SNMP Protocol – Built-in