National Instruments NI-VXI Network Card User Manual


 
Appendix A Specifications for VXI-MXI-2
PCI-MXI-2 for Linux A-6 ni.com
Requirements
VXIbus Configuration Space..................64 B
A24 or A32 Space...................................16 KB minimum (programmable)
Environmental
Temperature
Operating.........................................0 to 55 °C
Storage.............................................40 to 85 °C
Relative humidity
Noncondensing, operating...............0 to 95%
Noncondensing, storage ..................0 to 95%
EMI.........................................................FCC Class A verified
Physical
Board dimensions ...................................Fully enclosed, shielded VXI
C-size board 233.35 by 340 mm
(9.187 by 13.386 in.)
Connectors..............................................Single fully implemented
MXI-2 bus connector and
three SMB connectors
Slot requirements....................................Single VXI C-size slot
Compatibility..........................................Fully compatible with
VXI specification
VXI keying class ....................................Class 1 TTL
MTBF .....................................................Contact factory
Weight ....................................................1.027 kg (2.26 lb) typical
(no DRAM installed)