National Instruments NI-VXI Network Card User Manual


 
Chapter 4 VME-MXI-2 Configuration and Installation
© National Instruments Corporation 4-9 PCI-MXI-2 for Linux
Switch S2 is used to select the size of each SIMM. If the SIMMs are
4M× 32 or larger, S2 should be in the OFF setting as shown in
Figure 4-6a. For SIMMs smaller than 4 M × 32, use the ON setting as
shown in Figure 4-6b.
Figure 4-6. SIMM Size Configuration
Refer to Table 4-1 for how to adjust the switch (ON or OFF) for all
supported DRAM configurations. Many of the DRAM options are
available from National Instruments.
Table 4-1. VME-MXI-2 DRAM Configurations
Bank 0 Bank 1 Total DRAM
National
Instruments
Option
Switch Setting
of S6
0
256 K × 32 or
256 K × 36
1 MB ON
256 K × 32 or
256 K × 36
256 K × 32 or
256 K × 36
2 MB ON
512 K × 32 or
512 K × 36
2 MB ON
512 K × 32 or
512 K × 36
512 K × 32 or
512 K × 36
4 MB ON
1 M × 32 or
1M× 36
4 MB YES ON
1 M × 32 or
1M× 36
1 M × 32 or
1M× 36
8 MB ON
2 M × 32 or
2M× 36
8 MB YES ON
a. 4 M x 32 and Larger b. Smaller than 4 M x 32
S2
S2