NEC 5800/320Lb Server User Manual


 
7-16
On-screen error message Cause Action
0B29 Unsupported Processor
detected on Processor 2
The processor (CPU) not
supported by this server is
installed in Processor 2.
Install the CPU appropriate to
the server.
0B30 CPU FAN #1 Alarm
occurred
0B31 CPU FAN #2 Alarm
occurred
Dusts are clogged in fan.
Fan is faulty.
CPU module board is
faulty.
Replace the fan.
Replace the CPU module
board.
Connect fan cable
properly.
0B32 CPU FAN #3 Alarm
occurred
Dusts are clogged in fan.
Fan is faulty.
CPU module board is
faulty.
Replace the fan.
Replace the CPU module
board.
Connect fan cable
properly.
0B40 Invalid System
Configuration Data
Configuration error in
SETUP.
CPU/PCI module board is
faulty.
Reset the setting by
selecting [Yes] at [Reset
Configuration Data]
Replace the CPU/PCI
module board.
0B41 System Configuration
Data Read error
Configuration error in
SETUP.
CPU/PCI module board is
faulty.
Reset the setting by
selecting [Yes] at [Reset
Configuration Data]
Replace the CPU/PCI
module board.
0B42 Resource Conflict Configuration error in SETUP.
Correct device configuration in
SETUP
0B43 Warning: IRQ not
configured
Configuration error in SETUP. Correct settings in SETUP
0B44 Expansion Rom not
initialized
Configuration error in SETUP.
In SETUP, disable
decompression of expansion
ROM on unnecessary optional
PCI cards.
0B45 System Configuration
Data Write error
Configuration error in
SETUP.
CPU/PCI module board is
faulty.
Reset the setting by
selecting [Yes] at [Reset
Configuration Data]
Replace the CPU/PCI
module board.
0B47 Missing date and time
synchronization
The date and time are
incorrect due to a
communication error between
BMCs.
Restart the system.
Re-set the date and time
in SETUP.
If the error persists, replace the
PCI module board.
0B49 BMC Issued Reset
Command, but failed
System Reset
System cannot be reset by
BMC’s reset command.
Replace PCI module board.
0B6E DIMMs are installed out
of order
DIMM is faulty. Replace DIMM.
0B70 The error occurred
during temperature
sensor reading
SMBus device is faulty.
SMBus is faulty.
Replace the CPU/PCI module
or back panel board.