NEC 5800/320Lb Server User Manual


 
7-32
used is 32.
“APIC error” is recorded in the syslog by the operations such as inserting/removing
disks:
A message “APIC error” may be recorded to the log or displayed on the screen
when you perform operations such as inserting/removing disks with the server
powered on, because the internal status managed by the OS and the actual status
on the server side are different. The operations are not affected.
“info synchronization error” is recorded while the CPU modules are being
synchronized:
A message “info synchronization error” may be recorded in the log when the
CPU modules are performing duplication because the internal status managed by
the OS and the actual status on the server side are different. The operations are not
affected.
“card reports no resources” log is recorded when using the built-in LAN board:
A message “card reports no resources” may be output to the log when the system
cannot allocate the resource for the LAN driver due to high load ratio on the
network access. The operations are not affected. LAN driver performs retry
automatically thus the system continues communication without disconnecting the
network connection.
Problems with NEC EXPRESSBUILDER
When the server is not booted from the NEC EXPRESSBUILDER CD-ROM, check the following:
Did you set the NEC EXPRESSBUILDER during POST and restart the server?
If you do not set the NEC EXPRESSBUILDER during POST and restart the
server, an error message will appear or the OS will boot.
Is BIOS configuration correct?
The boot device order may be specified with the BIOS setup utility of the server.
Use the BIOS setup utility to change the boot device order to boot the system
from the CD-ROM drive first.
<Menu to check: [Boot]>