NEC EXP320A Server User Manual


 
Troubleshooting 7-9
On-screen error message Cause Action
9039 Not keep last boot
order
Unintended operations such
as incorrect DC off are
performed.
Reconfigure the boot option by
using the BIOS setup. If
reconfiguring the boot option
does not help, replace the
CPU/IO module.
9070 The error occurred
during water-cooling
unit sensor reading
The sensor of water-cooling
kit is faulty.
Replace the water-cooling kit. If
turning on/off AC does not help,
replace CPU/IO module or ft
Remote Management Card.
NOTICE System is force
boot with POST
error
Abnormality of one or both
sides of modules is detected.
View other error information and
the error information of standby
CPU/IO module.
9000 A serious error occurred
during a POST.
There are some error messages
in addition to this error code.
Check the other error message.
9007 Forced power off occurred by
another CPU/IO module has
a problem.
Pull out another CPU/IO module
and install it.
If this does not help, replace the
CPU/IO module.
9008 Forced power off occurred by
another CPU/IO module has
a problem.
Pull out another CPU/IO module
and install it.
If this does not help, replace the
CPU/IO module.
9010 - 9015 Can not boot from target Disk. Check the target disk.
In addition, replace it if required.
If this does not help, replace the
CPU/IO module.
9020 CPU is faulty. Replace the CPU.
If this does not help, replace the
CPU/IO module.
9022 - 9023 Initialization of the cross-link
between the CPU/IO modules
and access are faulty.
When the system is running in
the duplex mode, it is no
problem.
If the system cannot be running
in the duplex mode due to
continuous this error, replace the
CPU/IO module.
If this does not help, replace
another CPU/IO module or
center plane.
9024 Disconnect the cross-link
between the CPU/IO
modules.
When the system is running in
the duplex mode, it is no
problem.
If the system cannot be running
in the duplex mode due to
continuous this error, replace the
CPU/IO module.
If this does not help, replace
another CPU/IO module or
center plane.