NEC MC2400 Server User Manual


 
C-16
Emergency Management Port Console
Sensor Type Codes (continued)
Sensor Type and Number in
Verbose Sensor Name Generator ID
Voltage # 06 5V Standby BMC
Voltage # 07 Baseboard SCSI-A Term1 BMC
Voltage # 08 Baseboard SCSI-A Term2 BMC
Voltage # 09 Baseboard SCSI-A Term3 BMC
Voltage # 0A Baseboard –12V BMC
Voltage # 0B Baseboard SCSI-B Term1 BMC
Voltage # 0C Processor 1.5V BMC
Voltage # 0D Baseboard –5V BMC
Voltage # 0E Baseboard 12 BMC
Fan # 0F Baseboard Fan0 BMC
Physical Security #26 Chassis Intrusion BMC
Secure Mode Violation Attempt
#27
EMP password (at the time of
connecting to the server)
BMC
Secure Mode Violation Attempt
#28
Secure Mode Violation (while the
system is in Secure Mode)
BMC
Processor #1B Processor1 Status BMC
Processor #1C Processor2 Status* BMC
Memory # 1F DIMM1 Presence BMC
Memory #20 DIMM2 Presence BMC
Memory #21 DIMM3 Presence BMC
Memory #22 DIMM4 Presence* BMC
Post Error #25
Refer to
Problem Solving
Post
Error Codes and Messages
BIOS
Watchdog #25 Watchdog Event BMC
System Event #EF See the System Event Logging
Format Table
BIOS
*Not applicable to all servers