NetComm NP2724M Switch User Manual


 
2) monitor disable
This command disables port mirroring.
Format monitor disable
Mode Global Config
3) monitor des
Configure destination port.
3.1) monitor des <port-ID> probetype bidirection
This command configures port monitor probetype as bi-direction traffic.
Format monitor des <port-ID> probetype bidirection src <port list>
Mode Global Config
e.g. Switch(config)# monitor des 1 probetype bidirection src 2-8
3.2) monitor des <port-ID> probetype ingress
This command configures port monitor probetype as ingress traffic.
Format monitor des <port-ID> probetype ingress src <port list>
Mode Global Config
e.g. Switch(config)# monitor des 1 probetype ingress src 2-8
3.3) monitor des <port-ID> probetype egress
This command configures port monitor probetype as egress traffic.
Format monitor des <port-ID> probetype egress src <port list>
Mode Global Config
e.g. Switch(config)# monitor des 1 probetype egress src 2-8
dot1x
1) dot1x enable
This command enables global 802.1x function.
Format dot1x enable
Mode Global Config
2) dot1x disable
This command disables global 802.1x function.
Format dot1x disable
Mode Global Config
3) dot1x port-control
Configure port auto-authentication mode.
3.1) dot1x port-control enable
This command set auto-authorized on a list of ports.
Format dot1x port-control enable port <port list>
Mode Global Config
3.2) dot1x port-control disable
This command set force authorized on a list of ports.
Format dot1x port-control disable port <port list>
Mode Global Config
e.g. Switch(config)# dot1x port-control disable port 1-4
network
1) network mgmt-vlan
This command changes management vlan.
Format network mgmt-vlan <vlan-ID>
Mode Global Config
2) network parms
This command configures static IP address of the switch.
Format network parms <IP addr> <subnet mask> <gateway>
NP2724M User Manual 25