Network Technologies CS-16/8 Switch User Manual


 
NTI RACK MOUNT CONSOLE TERMINAL WITH CONSOLE SWITCH
12
3.1 Administrator Controls
3.1.1 Login as the administrator
1. The TERMINAL must first be configured (and is typically delivered preconfigured) as described on page 8 under "Getting
Started”.
2. Press [ Enter ] on the keyboard, wait three (3) seconds, and the port will open to the "Accessible host list" for "User01",
logged in at "Port00".
3. Press [ Esc] to logout, and [Y] to confirm. A message will be displayed "Disconnecting user now"
4. Press [Spacebar] or [ Enter]. A prompt requesting a Username will appear.
5. Enter
[root] (all lowercase letters) and press [ Enter]. A prompt for a password will appear.
6. Enter
[nti] (all lowercase letters) and press [ Enter]. The “Administrator main menu” will appear for user ROOT on
port 1.
Note: This will only enter the administrator mode if the administrator password has not yet been changed from "nti".
FYI: If SERIMUX is not at initial power-ON, omit steps 2 and 3 above to login.
Figure 8- Administrator main menu
FYI: The Administrator main menu will also appear if a user with administrative privileges presses [4] from the User main
menu.
From the Administrator main menu, the following options are possible
:
Function Description Keystroke
Port List Display the port list [1]
Port settings View or modify any port settings [2]
Port disconnect Disconnect any port and logout the user logged in or connected to the port [3] + [port #]
Port Connect Connect to any port . [4] + [port #]
User list Display the user list [5]
User settings View or modify user settings [6]
User disconnect/logout Disconnect and logout any user connected to a port [7]
Advanced settings View or modify advanced administrative settings (pg 17) [8]
Return to user menu Leave the administrative menu and return to the User main menu (only
listed when a user with administrative rights is logged in)
[9]
Logout Logout from SERIMUX [0]