Network Technologies CS-16/8 Switch User Manual


 
NTI RACK MOUNT CONSOLE TERMINAL WITH CONSOLE SWITCH
73
Appendix A - SERIMUX Port Characteristics
Every port is defined through the following parameters:
Description Acceptable Value Default Value
Number 0-8/16/24/32 Same (not changeable)
Name Up to 15 characters “Port00” to “Port32”
Type – port 0 User User (not changeable)
Type – except port 0 User or Host Host
Baud rate – port 0 300-115200 9600
Baud rate – except port 0 50-128000 9600
Data bits per character – port 0 7,8 8
Data bits per character – except port 0 5,6,7,8 8
Stop bits – port 0 1, 2 1
Stop bits – except port 0 1, 1-1/2, 2 1
Parity No parity, even, odd No parity
Handshake mode (flow control) Xon / Xoff (or in-band, or software),
RTS/CTS (or out-band or hardware),
Both,
None
None
Xon character any ASCII nonprintable character (0-31 range) Ctrl+Q (17)
Xoff character any ASCII nonprintable character (0-31 range) Ctrl+S (19)
Inter-character delay – except port 0
(no delay allowed on port 0)
1-60 milliseconds, none None
Line break receive allowance – except port 0
(no allowance for port 0)
Yes or No No
Transmitted line break extra duration (added
to 1 character transmission time) – except
port 0 (no extra duration for port 0)
No break transmitted, 1-999 milliseconds No break transmitted
In-band disconnect sequence 0 (disabled), 1, or 3 characters sequence 1-char sequence
1 character disconnect sequence Any ASCII nonprintable character (0-31 range) Ctrl+X (24)
3 character disconnect sequence Any 3 ASCII characters ``` (3 back quotes)
Connection timeout 1-90 minutes, never 15 minutes
DTR output upon disconnect Low, high, or pulsed for 0.5 seconds and then held
high
High
Modem Reset string Up to 41 characters ATZ
Modem Initialization string Up to 41 characters AT&F&C1&D2S0=0
Modem Disconnect string Up to 41 characters ATH
Appendix B - SERIMUX User and Administrator Characteristics
The users and the administrator are defined through the following parameters:
Description Acceptable Value Default Value
Users:
User number 1 to 32 Same (not changeable)
User name Up to 15 characters – case sensitive “User01” to “User32”
User password Up to 31 characters – case sensitive “” (empty string)
User enabled Yes or No Not enabled, except
User 1: enabled
Administrative privileges Yes or No No
Access to ports Port 0 always; Ports 1-31 Port 0, except
User 1: all ports
User menu timeout 1-90 minutes, never 15 minutes
Administrator:
Administrator name “root” – case sensitive Same (not changeable)
Administrator password Up to 31 characters – case sensitive “nti”
Administrator menu timeout 1-90 minutes, never 15 minutes
User to auto login User 1-32, None User 1