28
Serial Baud Rate
The serial baud rate for the UNIMUX can be changed by pressing <B> from the System Configuration menu. In order to control
the UNIMUX via RS232 (page 31), the baud rate must be set the same as the communication port on the control terminal
attached to the UNIMUX (page 9)
The baud rate value can be set to 115000, 57600, 38400, 19200, 9600, 4800, 2400, or 1200. A data protocol of 8 data bits, no
parity, and 1 stop bit is used for communications. With the edit field highlighted, press the <Left arrow> or <Right arrow>
to change the value of the baud rate.
Note: The baud rate can also be changed from the RS232 Command Protocol (see page 31).
For more on RS232 Control, see page 31.
Figure 36- Adjust Baud Rate
Serial Address
To allow multiple UNIMUXs to be controlled from a single control terminal, the RS232 control interface is designed to allow "daisy
chaining" up to 15 units. Each unit must be assigned a unique address. The unit address for the UNIMUX can be changed by
pressing <E> from the System Configuration menu. With the edit field highlighted, press the <Left arrow> or <Right
arrow> to change the value of the unit address. The address range is 1-15. For more on daisy chaining, see page 31.
Figure 37- Adjust Serial Address