Nokia A032 Network Router User Manual


 
Minor functional changes
17
SNMP changes
The A032 enterprise traps have been updated
since the previous issue of the user manual. The
following are now generated:
Trap Name Description
1 A032
Authenticate fail
Generated in the event that a station tries to associate
but is refused due to the fact that the NID Name
security feature is enabled. Note that this trap is
limited to being generated no more than once every
30 seconds to prevent flooding due to denial of service
attack.
2 A032 Bridge
Down
If the bridge/repeater function is active, this trap is
generated when a bridge link is lost.
3 A032
Management
login
Generated whenever the Management password is
successfully entered in one of the management
utilities.
4 A032 TFTP Access Generated whenever a TFTP transfer is initiated to or
from the unit.
5 WEP
Authenticate fail
Generated in the same way as Trap 1, but when the
authentication is rejected because of WEP rather than
the NID name feature.