Nortel Networks NN44200-700 Network Card User Manual


 
1002rp server 39
Windows and CallPilot hardware troubleshooting
Trouble Action
The system beeps but
otherwise seems to be
running properly and taking
calls.
This is a RAID card beep indicating that one of the drives does not
function properly. Do not shut down the system.
Open the MegaRAID utility and check which drive is marked as
Dead.
Rebuild the drive marked as Dead.
If the drive rebuild is not successful, ensure that the other drive
is functioning correctly.
Power down the system and replace the drive marked as Dead.
Voice services from the
Meridian 1 switch are not
available after an upgrade.
Ensure that the MGate card PEC is NTRB18CA or later.
Ensure that the version of the MPB16-4 board is 05 or later.
The system stops taking
calls after a powerful
lightning storm.
The DS30 part of the system is affected. Replace the MGate card
to which the MPB16-4 board is connected.
The system plays voice
prompts but does not
record messages(T1/SMDI
configurations only).
Ensure that your system has the latest version of the Ctbus.mcs file.
This file is located in the D:\nortel\hardware\board\m96\ folder.
The system is affected by
the following symptoms:
frame slips, crackling
voice, fax dots, and alarms
(T1/SMDI configurations
only).
Ensure that the MPB16-4 board is release 5 or later.
Ensure that the cable used for the T1 connection is supplied by
Nortel and is not a category 4 or 5 cable.
Ensure that the SCBus or CTBus cable is not defective.