Nortel Networks NN44200-700 Network Card User Manual


 
600r server 55
The system boots but a red CRT LED and an
amber PWR LED appears.
One power supply is faulty, or the AC cable is
unplugged (or faulty).
The system boots but PCI errors appear or fill
the screen.
Ensure the PCI raiser assembly is plugged in
correctly, aligned, and firmly pressed into the
slot. You must complete the reseating with the
server out of the rack and on a solid surface.
Ensure the power cable is plugged in.
The system boots, but a blue screen appears. Ensure the PCI raiser assembly is plugged in
correctly, aligned, and firmly pressed into the
slot. You must complete the reseating with the
server out of the rack and on a solid surface.
During an upgrade, the upgrade wizard states
that the processor configuration is incorrect.
Ensure the BIOS settings are correct (including
the hyper-threading setting).
The system starts to boot but two red lines
appear at the bottom of the screen and the
message cannot be read.
The server recovered from a system error
(processor internal IERR error). To clear the
resulting error message from the log, go to the
processor menu in BIOS and set the processor
re-test to enabled.
During startup, a message indicates that the
System Event Log is full and the log must be
cleared.
This is an unusual situation and appears only if
the server was booted many times. View the log
before clearing it. See the 600r Maintenance
and Diagnostics guide NN44200-703 for
viewing and clearing the System Event Log.
Server appears to boot but cannot find the hard
drive.
This is likely due to the absence of the SCSI
terminator on the back of the server. If the
tape drive is plugged in, ensure it has the SCSI
terminator installed.
SCSI and tape drive troubleshooting
Trouble Action
The SLR external tape drive is plugged in but is
not recognized by the device manager.
Select a device within the Windows device
manager and then select Action > Rescan. The
drive should be detected. If not, ensure the
correct driver is installed.
If this does not resolve the problem, ensure the
external drive is powered up and not faulty.
Observe the LED codes on the tape drive for
errors pertaining to the tape drive only.
Nortel CallPilot
Troubleshooting Reference Guide
NN44200-700 01.05 Standard
5.0 26 June 2007
Copyright © 2007, Nortel Networks
.