Nortel Networks 600 Switch User Manual


 
52 Chapter 4 Installing option cards and DIMMs
NN46110-308 02.01
Shutting down the system to add or replace hardware
Shut down the VPN Router 600, and unplug it to install or replace an option card
or to replace the DIMM.
To shut down the VPN Router 600:
1 Use the Web graphic user interface (GUI) or the command line interface
(CLI) to shut down the gateway.
Web GUI: Choose Admin > Shutdown. Select the option to power off the
gateway after shutdown.
CLI: Use the
reload command to shut down the system. For example,
enter
reload power-off disable-logins “Upgrade hardware”
(for the complete syntax of the reload command, see the Nortel VPN
Router Using the Command Line Interface (NN46110-507).
2 Wait for the system to shut down. You need to wait several minutes.
3 Remove all interface cables from the rear of the chassis.
4 Disconnect the power cord from the power outlet.
5 Disconnect the power supply cable from the VPN Router 600 DC input port.
Opening the Nortel VPN Router 600
To install an interface card or to replace the DIMM, you must remove the VPN
Router 600 chassis from its steel enclosure.
To access the chassis:
Warning: Risk of electric shock
Turn off the VPN Router 600 and unplug it before you attempt to
remove or install an option card or DIMM.