Nortel Networks V210 (RoHS) Server User Manual


 
NN42020-310 MCS 5100 3.5 Standard 1.0 June 2006
42
Copyright © Nortel Networks Limited 2006
7 Enter your password: system [Enter]
8 Define server ip address <IP address of the terminal server>
[Enter]
9 Define server ip subnet mask <ip-address of the subnet
mask> [Enter]
10 Define server ip primary gateway address <ip address of the
primary gateway> [Enter]
11 Define port:<select port from range 1-18> telnet newline
filtering cr [Enter]
Note: Type a range [1-18] for every port the Sun Fire V210
server is connected to.
12 Define port for use with SMDI: Define port 19 telnet newline
filtering none
Note: You can verify the ports with the command:show
ports 1-19 telnet chara [Enter]
13 Save your changes.
14 Log out.
Note: Using the command define saves the configuration.
15 To kill a session on a port, type: logout port 12 [Enter]
Procedure 9 Connecting a server to the MRV LX terminal server
At the management pc,
1 Connect a cat-5 Ethernet cable from the management PC to the
layer-2 switch.
2 Launch PuTTY.
Note: Refer to the customer-specific information datasheet to
enter the MRV LX terminal server IP address and the port
number.
3 In the hostname field, enter <IP address of the MRV LX
terminal server>
ATTENTION
The procedures in this document assume that you are using
PuTTY. It is suggested that you download from the web, PuTTY
VT 100 Emulator, a freeware configurator tool to set up sessions.
Download PuTTY from
www.chiark.greenend.org.uk/~sgtatham/putty/