5 You will see the following message:
Select the Type of Deployment:
[1] Initial Deployment
[2] Upgrade of Database
[3] Rollback of Database
[4] Install Files only to
Select 1 for initial deployment, then press Enter.
6 Enter Machine Logical IP Address - Primary DB:
Enter the <machine logical IP address of the MgmtSvr>, or press
Enter to accept default.
Example: 120.120.13.22
7 Enter the Machine Logical IP address -
Management Server:
Enter the <machine logical IP address of the MgmtSvr>, or press
Enter to accept default.
Example: 120.120.13.22
8 Enter the Service Logical IP address of the
SysMgr:
Enter the <service logical IP address of the SysMgr>, or press
Enter to accept default.
Example: 120.120.13.22
Note: Information obtained for database deployment
appears on the screen.
9 Is the above data correct? [Y]
Press Y to select the default or N to change.
Note: The imssipdb deployment begins. The installer will
notice the PuTTY window scrolling installation information.
This is the Management/Accounting server sending the
imssipdb data to the database server. Make sure that you
receive the "Successful Install" box at the end of the script
execution.