Revision 04062009 Page 13 of 52
APPLYING POWER (702M12-W)
The M12 A coded power connector is keyed, where the mating connection from the power supply
can be made only when the male and female ends are lined up properly.
Verify the Power LED stays ON (GREEN).
Notes:
Only 1 power supply must be connected to power for minimal operation. For redundant power
operation, V
1
and V
2
inputs must be connected to separate DC Voltage sources. This device will
draw current from both sources simultaneously. Use 16-28 gauge wire when connecting to the
power supply.
The LAN port supports Power over Ethernet and can be used redundantly with the power input
mentioned above.
Recommended 24V DC Power Supplies, similar to: N-Tron’s P/N NTPS-24-1.3:
Input AC 115/230V
Output DC 24-28V
Output Current 1.3A @ 24V
1.0A @ 28V
Power 72W
35 mm DIN-Rail Mountable
Dimensions: 45X75X91 mm