2-44 Color Calibration
C9800 Color Guide - 44
Calibrating the Fiery with the ES-1000
You can use ColorWise Pro Tools in conjunction with the ES-1000 to calibrate
the Fiery.
TO CALIBRATE THE FIERY USING THE ES-1000
1. Start Calibrator.
For instructions on starting Calibrator, see page 2-38.
2. Choose EFI Spectrometer ES-1000 as the measurement method.
3. In the Check Print Settings pane, choose the desired calibration set.
Choose the appropriate calibration set for the mode and type of media which are
needed for calibration.
NOTE: For this calibration to take effect, the calibration set must be associated with one
or more output profiles. There is no need to make any new associations for the default
calibration set, since it is already associated with the default output profile.
4. In the Generate Measurement Page pane, click Print.
The Print Options dialog box appears.
5. Choose the appropriate options and click Print.
For Page Type, choose either 21 or 34 Sorted
Patches, or 21 or 34 Randomized Patches.
Sorted patches are printed on the page in the
order of their hue and saturation levels.
Randomized patches are printed on the page in
random order, to help compensate for density
inconsistencies on different areas of the page.
Page Size is automatically set to LTR/A4 for 21
patches, or 11x17/A3 for 34 patches.
Input Tray is automatically set to Auto Select.
6. Retrieve the printed measurement page from the printer.