Omega Vehicle Security OM-550 Network Card User Manual


 
OM-550 u51u
POLLUTION DEGREE: Pollution Degree 2 per IEC Publication
664
This classification means that normally only non-conductive pollution (in the
form of dust) occurs. Occasionally, however, a temporary conductivity caused by
condensation must be expected.
INSTALLATION CATEGORY
(OVERVOLTAGE CATEGORY): Installation Category II per IEC
publication 664
This classification applies to products used on electric supply branch circuits.
This is defined as a classification of parts of installation systems or circuits with
standardized limits for transient overvoltages, dependent on the nominal line
voltage to earth.
POWER/CURRENT REQUIREMENTS
INTERNAL CELLS: 4-AA alkaline cells
OM-550 POWER INPUT: 9VDC, 50 mA (700 mA Peak while
printing)
AC POWER ADAPTER
INPUT: 120 VAC or 230 VAC, model-specific
OUTPUT: 9 VDC, 1 A, 9 W
EXTERNAL OPTIONAL BATTERY PACK: 12 VDC, Rechargeable,
FUSE FOR DC POWER CABLE: 2A/250V, 0.25" x 1.25" (6.3 mm x 32 mm)
BATTERY LIFE
INTERNAL CELLS: Approximately 8000 printed lines
PHYSICAL DIMENSIONS 4" W X 9.5" D X 1.5" H (with paper roll)
WEIGHT: 2 lb. (with batteries and paper)
CALIBRATION: NIST traceability
RECALIBRATION PERIOD: 6 months
WARRANTY PERIOD: 1 year
SHIPPING WEIGHT: 6 Lb.
CONNECTORS
ANALOG INPUTS: Miniature female thermocouple style
DC POWER: 5.5 mm X 2.1 mm (.216" X .080") male
jack
RS-232 DATA PORT: 4 Position 4 Circuit Modular (4P4C)