Manual No. 25-ULPNR101-03; Feb, 2003 LPN5627 / LPR5627 Laser Fixed Mount
Scanner
Page 1
Section 1
Introduction and Getting Started
Product Overview
The LPN5627 and LPR5627 (Raster) Fixed Position Scanners are miniature, 500 scan per second, laser
bar code readers designed to be easily incorporated into host equipment. The high scan speed and small
physical size make the scanner easy to integrate into any hardware design. Durability and reliability are
assured.
Advanced microprocessor technology coupled with Opticon’s proven decoding algorithms result in high
speed operation with superior accuracy. The scanners are fully programmable allowing the user to
customize parameters including changing communication settings, selecting symbologies, adding prefixes
and appending suffixes. Programmable settings can be downloaded from the host CPU or computer
directly to the scanner.
The scanners are encased in compact, rugged metal enclosures. The compact size permits installation in
the tightest areas allowing great flexibility in mounting and positioning the scanner for optimum
performance.
Quick Start-Up Procedure
This section is for those who wish to start using the scanner before reading the complete manual. Only a
few steps are needed to make the scanner operable.
A Developers Evaluation and Test board is available to allow rapid installation of the scanner
Connect the scanner min-DIN connector to the board
Using the DB9 extension cable, connect the board to a DB9 serial port, such as COM 1 on you PC.
Be sure your PC or host device is running an application such as HyperTerminal that will accept
serial input.
The default communications parameters of the scanner are 9600 baud, 1 Start/Stop Bit, 8 Data bits,
No Parity, No Handshaking, No Flow Control) See Users Manual for details on establishing or
changing communications parameters.
Plug the 5V DC power supply into the jack on the board
There is a trigger test button on the scanner. There is a trigger button on the Evaluation and Test
board as well.
That’s it. Your PC and the scanner should now communicate.
To verify that the scanner and the PC are communicating properly, send the following command from
your PC keyboard to activate the scanner’s buzzer.
Send the command: <Escape> V5 <Carriage Return>
Note: Be sure to use capital letters, e.g. “V5”, not “v5”.
The buzzer should sound, indicating that good communications have been established
To test the scanner, press the trigger test button on the scanner itself or on the evaluation board. A red