Manual No. 25-ULNFT2100-01; Mar, 2005 NFT 2100 CCD Fixed Mount Barcode
Scanner
Page 62
31. Redundant Decoding
The Number of Redundant Decodes determines how many times the scanner must decode a bar code
and obtain the same value before it will transmit the data. For example, if the redundancy is set at three
times, the scanner will not transmit data until it has completed three consecutive, identical “good reads”.
In the case of a poor label which generates an intermediate “no decode” within a sequence of four scans
where three of the four have resulted in “good reads”, the scanner will transmit the data after the fourth
scan. In other words, a “no decode” does not restart the sequence.
Computer
Command
Function
/Description
Bar Code
Command
(ZZ)
START/END
Programming Menu
[[
X2
Read bar code three times
Y3
%
X3
Read bar code four times
Y!
32. Transmitting Error Indications
Computer
Command
Function
/Description
Bar Code
Command
(ZZ)
START/END
Programming Menu
[[
WD
Disable ACK/NAK response to
sent command
XE
%
WC
Enable OK=ACK, ERROR=NAK,
response to sent command
XD