Panasonic KV-S2065W Scanner User Manual


 
27
Display Panel Instructions
Others setting menu (by pressing the OTHERS key)
Number, mode and default display
Pressing the
3
key will change to the
next mode.
Pressing the
4
key will change to the
previous mode.
Contents
Pressing the
1
key or the
2
key will change to another value.
01 Checking the version MX.XX :
FX.XX :
BX.XX :
Displays the mechanical control firmware version.
Displays the pre-imprinter firmware version. If a
pre-imprinter unit is not installed, the entry will
remain blank.
Displays the post-imprinter firmware version.
If a post-imprinter unit is not installed, the entry will
remain blank.
02 Setting the buzzer
03 Setting the SCSI ID
Setting the SCSI ID will be activated after turning the power off
and turning it on again.
04 Setting the terminator
When the scanner is located to terminal position on SCSI bus,
set to “Enable”.
Setting the terminator will be activated after turning the power
off and turning it on again.
The internal terminator works only when the unit’s power has
been turned on. If the PC is to be used while the unit’s power
is off, be absolutely sure to install an external terminator which
is available on the market.
05 Setting the transfer rate
Changes the maximum value of the synchronous transfer rate
of the SCSI interface.
Lower the synchronous transfer rate to 10 Mbytes/sec. if the
computer has failed to recognize the scanner or the scanner
fails to operate properly.