Panasonic RS-232C Projector User Manual


 
3/49
2. Basic Control Command
Explanatory notes
: Yes (Enable)
×: No (Disable)
: Case by case (Refer to the note.)
2.1. Power ON (Lamp ON)
Hexadecimal 02h 50h 4Fh 4Eh 03h
Character P O N
Response (Callback)
In the period when the command can be accepted (This command in power-on condition is included.)
Hexadecimal 02h 50h 4Fh 4Eh 03h
Character P O N
Acceptability
SECURITY STANDBY NO SIGNAL
AV MUTE
REMOTE
Notes:
When you confirm whether to have succeeded in power-on, confirm it by QPW (Query Power) command after
receiving the callback of PON command.
When REMOTE is effective, ER401 is returned as a response (callback).
2.2. Power OFF (Standby)
Hexadecimal 02h 50h 4Fh 46h 03h
Character P O F
Response (Callback)
In the period when the command can be accepted (This command in power-off condition is included.)
Hexadecimal 02h 50h 4Fh 46h 03h
Character P O F
Acceptability
SECURITY STANDBY NO SIGNAL
AV MUTE
REMOTE
Notes:
When you confirm whether to have succeeded in power-off, confirm it by QPW (Query Power) command after
receiving the callback of POF command.
When REMOTE is effective, ER401 is returned as a response (callback).
2.3. AUTO SETUP
Hexadecimal 02h 4Fh 41h 53h 03h
Character O A S
Response (Callback)
In the period when the command can be accepted
Hexadecimal 02h 4Fh 41h 53h 03h
Character O A S
Acceptability
SECURITY STANDBY NO SIGNAL
AV MUTE
REMOTE
× × ×
Note:
During NO SIGNAL, this command is available only when SIGNAL SEARCH is ON.
2.4. AV MUTE
Hexadecimal 02h 4Fh 53h 48h
3Ah
*1 03h
Character O S H : *2
Parameters (*1, *2)
AV MUTE OFF AV MUTE ON
Hexadecimal 30h 31h
Character 0 1
Response (Callback)
In the period when the command can be accepted
Hexadecimal 02h 4Fh 53h 48h 3Ah *1 03h
Character O S H : *2
Acceptability
SECURITY STANDBY NO SIGNAL
AV MUTE
REMOTE
× ×