43/49
2.133. Query FILTER INFORMATION
Hexadecimal 02h 51h 46h 49h 3Ah *1 03h
Character Q F I : *2
Parameters (*1, *2)
Runtime Rewinding
frequency
Filter kind Rewinding
interval
Elapsed time
after rewinding
Remaining
time
Hexadecimal 30h 31h 32h 33h 34h 35h
Character 0 1 2 3 4 5
Response (Callback)
Example: When "QFI:5" is transmitted, and the remaining time is 1,500 h
Hexadecimal 02h 31h 35h 30h
30h
03h
Character 1 5 0 0
Acceptability
SECURITY STANDBY NO SIGNAL
AV MUTE
REMOTE
○ × ○ ○ ○
Note:
• The remaining time returned by the response is a value of conversion, and it may differ from an actual value
depending on the environment and the condition.
2.134. Query CLOSED CAPTION SETTING
Hexadecimal 02h 51h 43h 43h 03h
Character Q C C
Response (Callback)
In the period when the command can be accepted
Hexadecimal 02h *1 03h
Character *2
Acceptability
SECURITY STANDBY NO SIGNAL
AV MUTE
REMOTE
○ × × ○ ○
Parameters (*1, *2)
OFF CC1 CC2 CC3 CC4
Hexadecimal 30h 31h 32h 33h 34h
Character 0 1 2 3 4
Note:
• Only when the model is PT-FW300NTU/FW300U/F300NTU/F300U, and the input signal is 480i or NTSC, this
command is available.
2.135. Query MAC Address
Hexadecimal 02h 51h 4Dh 41h 03h
Character Q M A
Response (Callback)
Example: AB0102030405
Hexadecimal 02h 41h 42h 30h
31h
30h
32h
30h
33h
30h 34h 30h 35h
03h
Character A B 0 1 0 2 0 3 0 4 0 5
Acceptability
SECURITY STANDBY NO SIGNAL
AV MUTE
REMOTE
○ × ○ ○ ○
2.136. Query Temperature Information
Hexadecimal 02h 51h 4Dh 41h 3Ah *1 03h
Character Q T M : *2
Parameters (*1, *2)
Intake air Exhaust air
Hexadecimal 30h 31h
Character 0 1
Response (Callback)
Example: 20°C (68°F)
Hexadecimal 02h 30h 30h 32h
30h
2Fh
30h
30h
36h
38h 03h
Character 0 0 2 0 / 0 0 6 8
Example: -10°C (14°F)
Hexadecimal 02h 2Dh 30h 31h
30h
2Fh
30h
30h
31h
34h 03h
Character - 0 1 0 / 0 0 1 4
Acceptability
SECURITY STANDBY NO SIGNAL
AV MUTE
REMOTE
○ ○ ○ ○ ○