36/49
2.109. Query DOT CLOCK
Hexadecimal 02h 51h 44h 43h
03h
Character Q D C
Response (Callback)
In the period when the command can be accepted
Hexadecimal 02h *1 *3 *5 03h
Character *2 *4 *6
Acceptability
SECURITY STANDBY NO SIGNAL
AV MUTE
REMOTE
○ × × ○ ○
Parameters (*1, *2, *3, *4, *5, *6)
-32 -31 -30
Hexadecimal 2Dh
33h 32h 2Dh
33h 31h 2Dh
33h 30h
Character - 3 2 - 3 1 - 3 0
30 31 32
Hexadecimal 30h 33h 30h 30h 33h 31h 30h 33h 32h
Character 0 3 0 0 3 1 0 3 2
Note:
• Only when the input is COMPUTER1 or COMPUTER2, and still image is displayed, this command is acceptable.
In other cases, ER401 is returned.
2.110. Query CLOCK PHASE
Hexadecimal 02h 51h 43h 50h
03h
Character Q C P
Response (Callback)
In the period when the command can be accepted
Hexadecimal 02h *1 *3 *5 03h
Character *2 *4 *6
Acceptability
SECURITY STANDBY NO SIGNAL
AV MUTE
REMOTE
○ × × ○ ○
Parameters (*1, *2, *3, *4, *5, *6)
-16 -15 -14
Hexadecimal 2Dh
31h 36h 2Dh
31h 36h 2Dh
31h 36h
Character - 1 6 - 1 6 - 1 4
14 15 16
Hexadecimal 30h 31h 34h 30h 31h 35h 30h 31h 36h
Character 0 1 4 0 1 5 0 1 6
Note:
• This command is acceptable only when the input is COMPUTER1 or COMPUTER2. In other cases, ER401 is
returned.
2.111. Query ASPECT
Hexadecimal 02h 51h 53h 31h
03h
Character Q S 1
Response (Callback)
In the period when the command can be accepted
Hexadecimal 02h *1 03h
Character *2
Acceptability
SECURITY STANDBY NO SIGNAL
AV MUTE
REMOTE
○ × × ○ ○
Parameters (*1, *2)
F300 series
AUTO
4:3 16:9 S4:3
THROUGH
Hexadecimal 30h 31h 32h 33h
34h
Character 0 1 2 3 4
FW300 series
AUTO 4:3 16:9 H-FIT
V-FIT
HV-FIT
THROUGH
Hexadecimal 30h 31h 32h 33h 34h 35h 36h
Character 0 1 2 3 4 5 6