Panduit TDP46H Printer User Manual


 
PANDUIT TDP4*HGMTDPH-MAN
Page 3-20
Section 3: Configuration
To exit the Card Mode, power the printer off and then back on.
SERVICE MODE
The Service Mode allows the operator to set up the basic operation parameters of the printer.
CARD MODE
V 05.00.03.00
INITIALIZING
ADVANCED MODE
SERVICE MODE
Displays the firmware during the initialization.
The Service Mode is entered from the Advanced Mode display by
pressing the LINE key twice.
The Service Mode display indicates that the printer is in the Card
Mode. To advance to the first selection, press the FEED key.
The TDP4*H printers determine the location of the leading edge of
the label by measuring the difference between light levels when it
sees either a label edge or a black “EYE” mark. This adjustment
allows you to manually set the threshold voltage level, between the
maximum and minimum light levels. DIP switch DSW2-2 selects the
sensor type. If DSW2-2 is in the OFF position, the setting will be for
a See-Thru (or Gap) sensor and the LCD will display “GAP” on the
top line along with the current setting. If DSW2-2 is in the ON
position, the LCD will display “EYE” on the top line with its current
setting. If the value entered for the bottom line setting is “0.0V”, then
the printer will automatically calculate the setting when the first label
is fed after the printer is powered on or the head is closed. There
are some instances where the automatically calculated value must
be adjusted to ensure reliable label feeding, such as when the
backing opacity or the reflectance of the EYE mark varies
significantly within a roll of labels or between label rolls. In these
instances the value should be set using the following procedures.
GAP [X.XXV]
INPUT [X.XV}