Paradyne 9128 standalone Network Router User Manual


 
3. Configuration Options
3-6 December 2002 9000-A2-GB31-00
LMI Status Enquiry (N1)
Possible Settings: 1, 2, 3, 4, . . . 255
Default Setting: 6
Configures the LMI-defined N1 parameter, which sets the number of status enquiry polling
cycles that the user side of the LMI initiates before a full status enquiry is initiated. Applies
to the user side of a UNI only.
1 – 255 – Specifies the number of status enquiry polling cycles that can be initiated before
a full status enquiry is initiated.
LMI Heartbeat (T1)
Possible Settings: 5, 10, 15, 20, 25, 30
Default Setting: 10
Configures the LMI-defined T1 parameter, which sets the number of seconds between the
initiation of status enquiry messages on the user side of the LMI. Applies to the user side
of a UNI only.
5 – 30 – Specifies the number of seconds between the initiation of status enquiry
messages in increments of 5.
LMI Inbound Heartbeat (T2)
Possible Settings: 5, 10, 15, 20, 25, 30
Default Setting: 15
Configures the LMI-defined T2 parameter, which sets the number of seconds between the
receipt of status enquiry messages on the network side of the LMI. Applies to the network
side of a UNI only.
5 – 30 – Specifies the number of seconds between the receipt of status enquiry messages
in increments of 5.
LMI N4 Measurement Period (T3)
Possible Settings: 5, 10, 15, 20, 25, 30
Default Setting: 20
Configures the LMI-defined T3 parameter, which is the time interval (in seconds) that the
network side of the LMI uses to measure the maximum number of status enquiry
messages that have been received (N4) from the user side.
5 – 30 – Specifies the interval of time in increments of 5.
Table 3-1. System Frame Relay and LMI Options (4 of 4)