Patton electronic 1214E Switch User Manual


 
Configuring the Hardware DIP Switches 22
CopperLink 1214E User Manual 3 • Configuration and Operation
Configuring DIP Switch S1
DIP Switch S1 is where you configure the Cop
perLink line. The following tables describe the configuration for
the 1214E.
Table 3. S1 Summary
Position Description
S1-1 Local/Remote Configuration
S1-2 Line Rate/Symmetry
S1-3 Line Rate/Symmetry
S1-4 Reserved
S1-5 SNR Margin
S1-6 Reserved
S1-7 Reserved
S1-8 Reserved
Switch S1-1: Local/Remote Configuration
Use Switch S1-1 to configure the unit as Remote or Local in the CL1214E.
Table 4. Local/Remote Unit Configuration
S1-1 Setting
ON CPE/Remote
OFF CO/Local
Switches S1-2 and S1-3: Symmetric/Asymmetric Operation
Use Switches S1-2 and S1-3 to configure the CopperLink line rate type-and operation.
Table 5. Symmetric/Asymmetric Selection Chart
S1-2 S1-3 Setting
OFF OFF High-Speed “Symmetric”
OFF ON High-Speed “Asymmetric”
ON OFF FastPath High-Speed “Asymmetric”
ON ON Long-Range “Asymmetric”
Note
See Appendix E on page 35 for line rate distances.