255 Supply type must be 0 (black mark), 1 (die cut), or 2
(non-indexed).
256 Ribbon selection must be 0 (direct) or 1 (transfer).
257 Feed mode must be 0 (continuous) or 1 (on-demand).
258 Supply position is outside the range. See "Defining the
Supply Setup Packet" in Chapter 3 for more information.
259 Contrast adjustment must be -390 to 156 dots.
260 Print adjustment must be -99 to 99 dots.
261 Margin adjustment must be -99 to 99 dots.
262 Speed adjustment must be 0 (default) or 20 (2.0 IPS).
263 Primary monetary symbol is invalid. See "Defining the
Monetary Formatting Packet" in Chapter 3 for more
information.
264 Secondary symbol selection must be 0 (none) or 1
(print secondary sign).
265 Monetary decimal places must be 0 to 3.
266 Character string length in the control characters packet
must be 5 (MPCL control characters) or 7 (ENQ/IMD
command character).
267 Baud rate selection must be 0 (1200), 1 (2400), 2
(4800), 3 (9600), 4 (19200), or 5 (38400). Resend the
communication settings packet or check the DIP switch
settings.
268 Word length selection must be 0 (7 bits), or 1 (8 bits).
Resend the communication settings packet or check the
DIP switch settings.
Errors 9-7