Paxar 9412 Printer User Manual


 
Be careful when using this feature. If you forget what the control
characters were changed to, print a test label. The test label lists
the current control characters. See "Printing a Test Label," in
Chapter 8 for more information.
Defining the Communication Settings Packet
Use the communication settings packet (F) to set the baud rate,
word length, stop bits, parity, and flow control for serial
communications. To set parallel communications, see "Using
Parallel Communications." Changing the communication settings
takes approximately two seconds. Communications sent during
this interval will be lost. Make sure the host communication
values match the values on the printer.
Syntax
{I,F,baud,word_length,stop_bits,parity,
flow_control p }
F1. F Communication Settings Packet
F2. baud Baud Rate. Options:
0 1200 3 9600 (default for all printers)
1 2400 4 19200
2 4800 5 38400
F3. word_length Word Length. Options:
0 7-bit word length
1 8-bit word length (default for all printers)
F4. stop_bits Stop Bits. Options:
0 1-stop bit (default for all printers)
1 2-stop bits
F5. parity Parity. Options:
0 None (default for all printers)
1 ODD parity
2 EVEN parity
F6. flow_control Flow Control. Options:
0 None 2 (CTS)
1 DTR (default 3 XON/XOFF
for all printers)
NOTE: If you use the DOS COPY command to download
your formats, set "Flow Control" to DTR (not
XON/XOFF).
Configuring the Printer 3-15