Pelco C841M-A Switch User Manual


 
C841M-A (7/02) 9
OPERATION
To operate the VA6200 Series Switcher:
1. Plug in the power cord.
2. Select the monitor by pushing the MON 1 or MON 2 button.
3. Press a camera button to view video from the corresponding camera.
SEQUENCING
To run a sequence:
1. Select a monitor by pushing the MON 1 or MON 2 button.
2. Press the SEQ button.
The camera LEDs light one at a time to indicate the corresponding camera is connected to the monitor. If a camera’s LED is not
lit, it has been programmed to bypass the sequence. Separate sequences can be run simultaneously on both monitors.
To stop a sequence:
1. Push the MON 1 or MON 2 button to select the monitor on which you want to stop the sequence.
2. Press any camera button.
The camera’s corresponding LED illuminates, sequencing stops, and the selected camera’s input appears on the monitor.
VIEWING THE STATUS OF CAMERAS IN A SEQUENCE
1. Press the MON 1 or MON 2 button.
2. Press and hold the GLOBAL and BYPASS buttons until the Sequence Status display appears on the monitor.
3. Release the GLOBAL and BYPASS buttons. If there is an asterisk under a camera on the monitor, that camera is IN the
sequence. If there is no asterisk, that camera is OUT of the sequence. Refer to Figure 7.
4. Repeat steps 2 and 3 to exit the Sequence Status mode.
CHANGING THE STATUS OF A SINGLE CAMERA IN A SEQUENCE
Camera inputs not used may be bypassed from the sequence. Likewise, cameras that are bypassed can be put back into the
sequence. To change the status of a camera:
1. Press the MON 1 or MON 2 button.
2. Press a camera button. If the camera LED is on steady, it is IN the sequence. If the camera LED is blinking, it is OUT of the
sequence.
2. Press the BYPASS button to toggle the status of the camera.
CHANGING THE STATUS OF MULTIPLE CAMERAS IN A SEQUENCE
Camera inputs not used may be bypassed from the sequence. Likewise, cameras that are
bypassed can be put back into the sequence. To change the status of cameras:
1. Press the MON 1 or MON 2 button.
2. Press and hold the GLOBAL and BYPASS buttons until the Sequence Status display
appears on the monitor.
3. Release the GLOBAL and BYPASS buttons.
4. Press the camera buttons to toggle the status of the cameras. Refer to Figure 7.
5. Repeat steps 2 and 3 to exit the Sequence Status mode.
In the sequence
Out of the sequence
Figure 7. Camera Status
MON 1 SEQUENCE STATUS
12345678
** ** *
MON 2 SEQUENCE STATUS
12345678
** ** **