Step 4
Function Action Result
a. Enter the Main Menu.
b. Press 2.
c. Enter the desired monitor number (01-04) or pan left/
right to show the desired monitor number.
d. Move down to highlight the ALARM TYPE: field.
e. Use the F1 and F2 keys to find the desired alarm
type.
f. Move down to highlight the ALARM DWELL field.
g. Use the keypad to enter the desired dwell time
(1 to 99 seconds).
h. Move down to highlight the DISPLAY field.
i. Use F1 and F2 to toggle the character display on or
off.
j. Move down to the 1. CAMERA SEQUENCE field.
k. Pan right.
l. Use the position keys or joystick to move around the
menu. Set Camera Number (1-16), Dwell Time (1-99
sec.) and Preset number for each camera in the
sequence. Enter zeroes to skip a camera.
m. Move down to RETURN.
n. Pan right.
Program
Monitors
Alarm Type:
Manual – must
press ACK to reset.
Auto – alarm resets
10 seconds after
alarm normalizes.
Off – no alarms
shown.
Alarm Dwell:
1 to 99 seconds –
time between
display of multiple
alarm screens.
Character Display:
On or off.
Program Camera
Sequences:
Each monitor can
have one 16-step
sequence. Set dwell
time and preset
number for each
camera.
The Main Menu appears.
The Monitor NN screen appears. NN is the monitor
number. The monitor number flashes.
The selected number appears on screen.
The current alarm type for the selected monitor
appears on screen.
The selected alarm type appears.
The current alarm dwell for the selected monitor
appears on screen.
The entered dwell time appears.
The current status of character display appears.
Asterisk (*) = on, dashes (--) = off.
The 1. In the 1. CAMERA SEQUENCE field flashes.
The Monitor NN Sequence Menu appears.
The entered values appear.
The R in RETURN flashes.
The Monitor NN screen appears.
ACK
Enter Monitor # (1-4).
Select Alarm Type
(Off, Auto, Manual).
Set Alarm Dwell
(0-99 sec).
Turn display On/Off.
Keypad
F1/F2
Keypad
F1/F2
Enter Monitor #.
Set Dwell time (1-99 sec)
and Preset number
for each camera
in the 16-step sequence.
Enter Monitor #.
Turn each alarm on/off
(*/--).
Move text around on the
screen to place it in the
desired location.
Press ACK when done.
Keypad
Keypad
Keypad
F1/F2
Pan/Tilt
PROCEDURE METHOD
PROCEDURE METHOD
PROCEDURE METHOD
PROCEDURE METHOD
ALM SET ALM SET ALM SET
RETURN
ALARM DWELL: 05
DISPLAY: *
1. CAMERA SEQUENCE
2. ALARM ENABLE
3. POSITION DISPLAY
MONITOR XX
ALARM TYPE: AUTO
RETURN
MONITOR XX ALARM ENABLE
ENTRY 1-8 ENTRY 9-16
01 02 00
02 02 00
03 02 00
04 02 00
05 02 00
06 02 00
07 02 00
08 02 00
09 02 00
10 02 00
11 02 00
12 02 00
13 02 00
14 02 00
15 02 00
16 02 00
CAM DWL PRE CAM DWL PRE
1 -- 7 -- 13 --
2 -- 8 -- 14 --
3 -- 9 -- 15 --
4 -- 10 -- 16 --
5 -- 11 -- 17 --
6 -- 12 -- 18 --
DISPLAY
SHOWING
POSITION
OF TEXT
MONITOR XX SEQUENCE MENU