28 Pelco Manual C523M-H (6/05)
Table B. Programming the CM6700 Switching Control Unit (Continued)
Step 6
Function Action Result
Program a. Enter the Main Menu.
Alarms 1-16
b. Press 4.
c. Pan right.
d. Move down to the ALM ENABLE 1 field.
e. Use the F1 and F2 keys to toggle the Alarm Enable
field (* = ON, -- = OFF). If you selected OFF go to
step k; otherwise, go to the next step.
f. Pan right.
g. Use the F1 and F2 keys to toggle the Alarm TYPE
field (NO = normally open contacts, NC = normally
closed contacts).
h. Pan right.
i. Use the keypad to select the desired preset (that the
camera will assume when an alarm occurs) for this
alarm number.
j. Pan right.
k. To program another alarm, go to step l. When you
have finished programming the alarms in this group,
go to step m.
l. Move down to the next ALM ENABLE field. Repeat
steps e through k for the next alarm.
m. To program group 2 (INPUT 9-16), go to step n.
When you have finished programming the alarms in
group 2, go to step r.
n. Move up to the Set Alarm Input 1-8 screen.
The Main Menu appears.
The Set Alarm Input screen appears. Alarms are
programmed in two groups. The Group 1 (INPUT
1-16) number flashes.
The Set Alarm Input 1-8 screen appears. 1-8
flashes.
The entry in the ENABLE field flashes.
The selected value flashes.
The entry in the TYPE field flashes.
The selected value flashes.
The entry in the PRESET field flashes.
The selected value flashes.
The Alarm 1 ENABLE field flashes.
The entry in the ENABLE field flashes.
The Set Alarm Input 1-8 screen appears. 1-8
flashes.
PROCEDURE METHOD
Turn Alarm on/off
Select alarm source Type
(NO, NC).
Enter Preset to go to
when alarm occurs.
(*/--).
F1/F2
F1/F2
Keypad
Select 1-8 or 9-16.
F1/F2
SET ALARM INPUT
1. INPUT 1-16
2. INPUT 17 AND 18
RETURN
1 -- NO 00
2 --
3 --
4 --
5 --
6 --
7 --
8 --
NO 00
NO 00
NO 00
NO 00
NO 00
NO 00
NO 00
ALM ENABLE TYPE PRESET
RETURN
SET ALARM INPUT XX
(Continued on next page)