Pentair SunTouch Network Card User Manual


 
56
SunTouch Pool and Spa Control System Installation and User’s Guide
Installing and Connecting Temperature Sensors
Water Temperature Sensor
To install the water sensor:
1. Select a convenient location to mount the water sensor in the plumbing system between the filter
pump and filter. Drill a 5/16" diameter hole in one side of the pipe,
2. Insert tip of sensor into the hole. Use the band clamp to secure the sensor to the pipe. Tighten the
clamp just enough so that the o-ring begins to flatten. Do not overtighten
3. Run 22 gauge two-conductor cable (included) between the sensor SunTouch motherboard. Route the
wire up through the low voltage raceway to the motherboard.
4. Fasten the cable to the plumbing with cable ties.
5. Cut off the excess wire and the strip conductors ¼ inch. Use waterproof connectors (provided) to
connect the sensor to cable. Insert the wires into the WATER SENSOR screw terminals (J9) on
right-side of the motherboard. For SunTouch motherboard wiring connections, refer to “SunTouch
Motherboard Connections,” on page 51.
Ambient Air Temperature Sensor (for freeze protection)
The SunTouch system will automatically detect an installed air sensor to protect the system if freezing
conditions occur. By default, the air sensor is always ON. Freeze protection for a “Solar Only” system
requires an additional air sensor (P/N 520272). To disable the air sensor, see “Advanced Menu (8/13): Air
Sensor” on page 24.
To install the air sensor:
1. Mount the sensor in the open air, in a shaded area, away from air conditioners. During the winter
months, to avoid freeze damage to pool and spa equipment, mount the air sensor in a shaded area to
assure proper temperature readings. The SunTouch main screen displays the current ambient air
temperature.
2. Route the wire through the low voltage raceway to the motherboard.
3. Fasten the cable to the plumbing with cable ties.
4. Cut off the excess wire and the strip conductors ¼ in. Insert the wires into the AIR screw terminals
(J9) on right side of the motherboard.
Solar Temperature Sensor
Run a two-conductor cable between the sensor and the SunTouch enclosure.
To install the solar sensor:
1 Mount the sensor on a flat surface, with the same exposure to sun as the solar collectors (next to the
collectors is recommended) or any sunny location. Do not let the sensor touch the panels.
WARNING: DO NOT DRILL HOLE AND CLAMP SENSOR INTO SOLAR PIPE. For
glazed panels, install the sensor between collector and glazing.
2 If necessary, splice a two-conductor extension wire to the sensor. Run two-conductor cable between
the sensor and the SunTouch Power Center. Use waterproof connectors to connect the sensor to the
cable. Use twisted pair 20 AWG outdoor rated sensor wiring and be sure the wire connections are
protected from the environment. Use shielded cable for long runs or runs near other electrical wiring.
3 Strip the conductors ¼ in. Insert the wires into the SOLAR SENSOR screw terminals (J9) on right
side of the motherboard.