Perle Systems S-1110DP Switch User Manual


 
Perle PoE/PoE+ Ethernet Media Converter
Installation Guide
18
Installing the Simplex Fiber Cable
1. Locate a 1000Base-X compliant simplex (1 strand) fiber cable
with appropriate connectors. Ensure that the TX wavelength
matches the RX wavelength at the other end and the RX
wavelength matches the TX wavelength at the other end.
2. Connect the fiber cable from one media converter to the other
media converter/switch/fiber device.
Installing the Copper Cable
1. Locate 10/100/1000Base-T compliant copper cables with the
appropriate connectors.
2. Connect the RJ-45 cable between the Perle media converter
and the device.
Note: The Perle media converter supports Auto-MDIX which
allows connection of a straight-through or cross-over Ethernet
cable.
Grounding the Media Converter
If your installation requires additional grounding the following
procedure can be followed.
Grounding the chassis requires the following items:
One grounding lug (not provided).
One 18 - 12 AWG wire (not provided).
Cross-head screwdriver (not provided).
Note: For your safety, when installing this equipment, always
ensure that the chassis ground connection is installed first and
disconnected last.