Perle Systems S-1110DP Switch User Manual


 
Perle PoE/PoE+ Ethernet Media Converter
Installation Guide
6
Installation
The default DIP switch settings (all switches in the UP position)
will work for most installations.
These are the steps required to configure the Perle S-1110P
Ethernet media converter:
1. Insert SFP Module (SFP Model only).
2. Set the Auto-MDIX jumper setting (optional).
3. Set the DIP switch settings (if required).
4. Set the Powering Option Jumpers (if required).
5. Install and connect the fiber cable(s).
6. Install and connect the copper cable(s).
7. Power up the media converter.
Auto-MDIX Jumper Settings
Note: The factory settings for Auto-MDIX will work for most
installations, but in the rare case that you need to modify the
settings, the procedure is below.
For dual copper media converters, each copper interface has an
Auto-MDIX jumper bank. To access the Auto-MDIX jumper
settings, unscrew the six side screws on the case and remove the
cover plate. Locate the MDIX AUTO jumper set as detailed below.
By covering or strapping pins 1 and 2, the S-1110P will operate as
an MDIX device. By covering or strapping pins 2 and 3, the S-
1110P will automatically detect the Ethernet cable’s polarity.
Removing the strapping is the same as AUTO.
Note: The default jumper setting is AUTO