Philips FMod-TCP BOX Network Card User Manual


 
49 / 58
TCP TIMEOUT
Register Address Register Name Function Read/Write Control
0x14
TCPTIMEOUT
Timeout for TCP
connection
Read/Write
Register Size Register structure Unit
1 Byte Unsigned Int 8 bits sec
Description:
The TCP timeout is a value (in seconds) after which the user will be
disconnected if the device has not been accessed in the meantime.
If the value is 0, the TCP timeout is deactivated. In this case however, if the
client crashes during connection, the communication will never be closed on
the module’s side! Because a maximum of 4 communications are allowed at
the same time on the module, one of them will be blocked. If the client
crashes four times, all of the 4 communications will be blocked and the
module will have to be reset!
The timeout for each TCP/IP connection is reloaded when there is traffic
through the port.
Default value:
30
Limitations:
Max value: 255
FMod-TCP User Manual v.2.8