Planar LC1200R Computer Monitor User Manual


 
LC1200R User’s Guide
021-0183-00 Rev A 25 of 29
Council Directive 89/336/EEC, 92/31/EEC and 93/68/EEC (Latest Amendment) on the approximation
of the laws of the Member States relating to electromagnetic compatibility is based on compliance
with the following harmonized standards:
Electromagnetic Emissions EN 55022 Class A: 1994
Electromagnetic Immunity EN 50082 part 1:1992
9.3 RFI Emission Certification
The LC1200R is certified to the following emissions standards when installed in customer product
configuration:
FCC, part 15, paragraph 15.107(b) and 15.109(b), Class A RFI emissions standard.
EN 55022 Class A: 1994 • Limits and measurements of radio interference characteristics of
information technology equipment.
IEC 1000 3-•2/1995; EN 61000-•3-•2 Current Harmonic Tests
IEC 1000 3-•3/1995; EN 61000-•3-•3 Voltage Fluctuation and Flicker Test
9.4 System Transient Disturbance Requirements
The LC1200R meets the following system transient disturbance requirements:
9.4.1
Electrostatic Discharge
The LC1200R performs normally when subjected to static electricity discharges from persons
touching the external surfaces of the LC1200R. Performance is verified by testing according
to EN 50082-1 (Ref IEC 801-2:1984) at severity level 3 (4 Kv contact discharge, 8 Kv air
discharge).
9.4.2
Electromagnetic Energy Susceptibility Requirements
The LC1200R performs normally in an electromagnetic field with a strength of 10-volts per
meter from 10 KHz to 1 GHz. (REF CISPR 22).
9.5 Labeling
Where applicable, the LC1200R complies with IEC 60417 – Graphical Symbols for Use on Equipment