Planar LC1200R Computer Monitor User Manual


 
LC1200R User’s Guide
021-0183-00 Rev A 9 of 29
2.11 Button Board
The button board controls the user controls noted in Section 6.1 LCD Controller Board Controls It can
be removed or mounted in another area after initial adjustments are made.
3 Environmental
3.1 Temperature and Humidity
The LC1200R withstands operating and storage environmental conditions listed in Table 2.
Table
Table Table
Table 2
22
2
General Operating
General OperatingGeneral Operating
General Operating
Shipping and Storage
Shipping and StorageShipping and Storage
Shipping and Storage
Comments
CommentsComments
Comments
Temperature
TemperatureTemperature
Temperature
0°C to 60°C
[32°F to 140°F]
-20°C to 60°C
[
-4°F to 140°F]
Note 2,3,4,5
Relative
Relative Relative
Relative
Humidity
HumidityHumidity
Humidity
Note 1 Note 1 Without
Condensation
T
air
is defined as ambient air temperature surrounding the LC1200R.
Note 1: T
air
< 32°C : 95% RH maximum.
T
air
> 32°C : Absolute humidity content not to exceed 100% at 32oC.
Note 2: T
air
@ -20°C < 48 hours
T
air
@ 60°C < 168 hours
Note 3: Slight background color changes are allowed depending on ambient temperature.
This phenomenon is reversible.
Note 4: High temperature operation assumes the use of an enclosure that properly directs the
fan airflow
Note 5: Upper operating temperature limit of 60°C is without solar loading.
Reference to "room ambient" is interpreted as 20°C - 25°C [68°F°- 77°F] and applies throughout this
specification unless otherwise noted.
For product reliability predictions, the assumed temperature profile is:
Table
Table Table
Table 3
33
3
Operating Time
Operating TimeOperating Time
Operating Time
Temperature
TemperatureTemperature
Temperature
5% 0°C [32°F]
90% 30°C [86°F]
5% 60°C [140°F]