Printronix L1524 Printer User Manual


 
3–41Configuring the Printer
Printer Control Menu
Fuser
Temperature
Printer Control
Normal *
–5 degrees C
–10 degrees C
+15 degrees C
+20 degrees C
+25 degrees C
+10 degrees C
+5 degrees C
Energy
Timeout
1 minute
5 minutes *
10 minutes
30 minutes
Disabled
No Retract
Mode
Ignore
Errors
Check TOF
Lever
Paper Ctrl
Err
Disabled*
Enabled
Disabled*
Enabled
Enabled*
Disabled
* = Factory Default
1
=
If Installed
Fuser Temperature
The fuser temperature option allows you to reduce the normal temperature of the
fuser by up to –10 C or increase to +25 C. A temperature reduction may be
required due to the print media. For example, thinner material may curl or waffle
at high temperatures and adhesive material on label material may melt. It is
necessary to lower fuser temperature in such cases. The selections on the
control panel are: Normal (this is the default selection), –5 degrees C, –10
degrees C, +15 degrees C, +20 degrees C, +25 degrees C, +10 degrees C, and
+5 degrees C.
Energy Timeout
The energy timeout option provides the ability to select the length of time before
the printer goes into the energy saving mode. From the energy saving mode, the
printer will require warm up time to bring the fuser to the configured temperature.
Energy is saved by turning off heater power to the fuser. The timeout selections
are: 1 minute, 5 minutes (this is the default selection), 10 minutes, 30 minutes,
and Disabled.
No Retract Mode
The default is Disabled. In this mode, the paper will retract into the printer while
printing. If enabled, the paper will not retract into the printer while printing.