Proxima ASA 7910 Network Card User Manual


 
85
Message Format:
BYTE response (ASCII ‘s’, 73H)
BYTE seqno (from original command)
BYTE subchannel (1 to 15, from original com
mand)
Baud Rate Confirmation
Purpose: This message is sent after a Set Baud Rate command is
received by the Serial Adapter. Note that this message is sent at
the old baud rate. The Serial Adapter switches to the new baud
rate immediately after this response is sent.
Message Format:
BYTE response (ASCII ‘b’, 62H)
BYTE seqno (from original command)
BYTE baud rate (02H to 0AH, from original
command)
Station Search Reply
BYTE response (ASCII ‘a’, 61H)
4 BYTES Serial number (IP address) of responding
station
RangeLAN2 Parameter Confirmation
BYTE response (ASCII ‘o’, 6FH)
BYTE seqno
BYTE Function number
BYTE status
0= success
1= error