MBE Family Installation and Operation Manual Chapter 2 Installation
Installation and Setup 2-5
Table 2-1. MBE Switches and Jumpers
Switch/Jumper
Name
Reference Possible
Settings
Factory
Setting
Description
LOCATION
SW1
Figure 2-1
REMOTE
MAIN
MAIN
MBE is located on the remote LAN.
MBE is located on the main (local)
LAN.
CHASSIS
(Ground
Connection)
JP7
Figure 2-1
NC
(Not Connected)
ON
(Connected)
NC Disconnect signal ground from chassis
(protective) ground.
Connect signal ground to chassis
(protective) ground.
RESET
(Front panel button)
Figure 2-1
System Reset
EPROM SIZE
Figure 2-1
512 KB
128 KB
128 KB
For manufacturer's use only.
WATCH DOG
Figure 2-1
OFF
ON
ON
For manufacturer's use only.
CLOCK SPEED
(4W Interface only)
Figure 2-2
7 – 16 kbps
6 – 32 kbps
5 – 48 kbps
4 – 64 kbps
3 – 96 kbps
2 – 128 kbps
1 – 256 kbps
0 – 768 kbps
768 kbps
Select data rate on 4-wire internal
modem.
Select the highest possible data rate for
respective range and wire gauge.
DTE/DCE Jumper
(V24, V35 Interface
only)
Figure 2-3
DTE
DCE
DTE Select DTE mode for normal
operation.
Select DCE mode for bench testing.
STATION HUB
Switch
(UTP Interface only)
Figure 2-4
STATION
HUB
HUB
Interchanges the Rx pair with the Tx
pair.