RCA Fibre Channel Switch Switch User Manual


 
22 Fibre Channel Switch 16 April, 2003
Trap Severity Options
---------------------
unknown, emergency, alert, critical, error, warning, notify, info, debug, mark
Contact (string, max=32 chars) ["On-call engineer"]
Location (string, max=32 chars) ["Rack 3-B"]
Trap1Address (dot-notated IP Address) [192.168.217.5]
Trap1Port (decimal value) [162]
Trap1Severity (see allowed options above) [warning]
Trap1Enabled (True / False) [True]
Trap2Address (dot-notated IP Address) [192.168.216.48]
Trap2Port (decimal value) [162]
Trap2Severity (see allowed options above) [warning]
Trap2Enabled (True / False) [True]
Trap3Address (dot-notated IP Address) [0.0.0.0]
Trap3Port (decimal value) [162]
Trap3Severity (see allowed options above) [warning]
Trap3Enabled (True / False) [False]
Trap4Address (dot-notated IP Address) [0.0.0.0]
Trap4Port (decimal value) [162]
Trap4Severity (see allowed options above) [warning]
Trap4Enabled (True / False) [False]
Trap5Address (dot-notated IP Address) [0.0.0.0]
Trap5Port (decimal value) [162]
Trap5Severity (see allowed options above) [warning]
Trap5Enabled (True / False) [False]
ReadCommunity (string, max=32 chars) [public]
WriteCommunity (string, max=32 chars) [private]
TrapCommunity (string, max=32 chars) [public]
AuthFailureTrap (True / False) [False]
Do you want to save and activate this snmp setup? (y/n): [n] y
Your monitoring station should now receive all traps from your Fibre Channel switch.
You can test this by creating a fault condition, such as disconnecting one of your Fibre
Channel connections to the Fibre Channel switch. A message should appear in the
NetCentral manager.